News & Events

    UK Head Office

    News & Events

     Our Head Office in UK ,address: 5 Jupiter House, Calleva Park, ...

    Read More

    ISO CERTIFICATION (9001 ,14001)

    News & Events

    A.T.GENERATORS became ISO CERTIFIED COMPANY , we proudly announce th...

    Read More
    View All...

    Our Products

    Diesel Genset

    Diesel Genset :

    We have a wide range of diesel generators from different brands powered by Perkins diesel generators, Cummins diesel generators, Volvo diesel generators, Kubota diesel generators, Mitsubishi diesel generators, Yanmar diesel generators &PXS diesel generators. We offer Portable Generators, residential Generators, industrial generators & Standby Generators.Our gensets meet all essential international and national standards. We recommend diesel generators due to their longevity and lower operating costs;

    We are profficional in generators sale, our main markets are in UK , Africa ,UAE & Iraq ,also for the rest of the middle east.

    Features of our generators

    • Rapid product availability
    • Proven reliability and low life–cycle costs
    • High efficiency and operational flexibility of the generators
    • High quality electrical performance
    • Well–established service and fuel supply infrastructure
    • Optional factory–integrated exhaust aftertreatments reduce emissions for high–hour use in environmentally sensitive locations.
    • Match the world famous alternators like stamford alternator, Leroy somer alternator, strict tests before the generator sale , the technology and quality can reach the best international standard. It features at low oil consumption, stable performance, easy maintenance,

    Read More
    Mobile Lighting Towers

    Mobile Lighting Towers:

    Mobile lighting towers gensets are available from different brand with different sizes OUR Lighting Towers genset are built to last and can withstand any type of weather condition. These Light Towers offer 360 degree rotation and can illuminate up to 7 acres. We have Malishia 7000Series(ML7000, ML7000M, ML7000K, ML7000P) the most advanced Winch-operated light tower on the market.

    Also we have the 6600 series consists of an :

    Heavy-duty trailer, four floodlights and a diesel-driven generator set mounted in an weatherproof enclosure for quiet operation.

    Operator control and troubleshooting are easier with centralized control panel and total protections to diesel engine.

    The 7000 seriesof the lighting towers genset has premium features not available on other cable-operated.

    Light towers genset they equipped With reliable Stamford or Leroysomer altenator.

    Applications of the lighting towers:

    • Mining, Construction and tunnel applications.
    • Airports and wharfs.
    • Defense operations.
    • Disaster relief and emergency relief.
    • Public areas.

    The other brand we have is Lombardini light tower which the tower light reach up to 9 meter in hight,water cooled, work with diesel, two wheels trailor with leaf springs. Weather proof canopy with tow doors from both sides, the side & roof arebolt fixed for easy maintenanceof the lighting tower genset.


    Read More
    CANOPIES

    Canopies:

    Weather and Sound Proofs are canopies specially designed and manufactured according to high production standards to fit for Gensets(diesel generators) tough weather conditions proofing and sound proofing. They also protect the generating set and increase its durability.

    We also have Mobile canopiesfor the diesel generators.

    • We offer Custom generator enclosures - weather resistant to super silent models to meet the most stringent noise level requirements!
    • 75db / 3m
    • Robust/Highly Corrosion Resistant Construction
    • Excellent Access for operation and Maintenance of the genset.
    • Two doors on the side or one door based on the size of canopy, convenient to install, watch, operation or maintenance or other appropriate place set watching window to watch the panel of controller which make it easy to control the generator.
    • Lube oil and cooling water drains piped to exterior of the enclosure
    • Simply, convenient operation, not need building generator room, usingat the open air
    • Setting silencer, on reaching destination, generator can work at any moment.
    • Lifting points on base frame which makes lifiting the generators easy.
    • Lower noise and lower exhaust from the generator

    Optional Equipment used for the diesel generators:

    • 080” aluminum modular panel construction resists rust and is assembled using tamper and corrosion resistant fasteners.
    • 3” aluminum tube frame allows the enclosure be removed as a unit without having to be disassembled.
    • Fixed vane intake Louvers are sized per the engine’s cooling and combustion airflow requirements.
    • Recessed latches for easy access.
    • Equipped with silencer mounting hardware, watertight roof pass-through, and tailpipe.
    • Exhaust Rain Shield and Collar.
    • All GPC enclosures can be unified with sub based fuel tanks; using base frames or as a drop over, direct to the concrete pad.
    • All GPC panels are sandblasted to achieve maximum adhesion and durability of the finish.
    • Two-part epoxy primer and high gloss finish polyurethane topcoat available in multiple colors.
    • System brand name decals.
    • Continuous drip edge around the entire perimeter of the enclosure’s roofline.
    • A ¼” x 2” medium density foam tape is placed between the enclosure and the tank, trailer, or frame to form a weather tight seal.
    • Hinged Keyed Alike lockable doors.
    • Exhaust Extension – Connects the Flex and the silencer.
    • Punched Radiator Guard.
    • Mounting of customer supplied battery charger.
    • Installation of customer supplied Flex Fuel Lines.
    • GPC enclosures can also be purchased in multiple types of material such as galvanized, steel, or stainless steel.
    • Electrical Support Packages may include 10 or 30 main lug or main breaker panels, vapor tight fluorescent or incandescent lights, GFCI duplex outlets, battery charger, and block heaters.
    • Battery Back-Up Emergency Lighting.
    • Internal exhaust system.
    • Water tight, tamper proof radiator cap access.
    • Auxiliary Equipment Installation and wiring for turnkey and parallel applications.
    • Gravity operated radiator outlet Louver that grants fail-safe operation and prevents precipitation from getting in while defending the radiator from the harsh conditions of the environment.
    • Walk in applications with personal door and steps to provide maximum accessibility.
    • Stainless steel 3-point latches.
    • Generator Output Circuit Breakers and wiring.
    • Provisions for internally mounted silencer.
    • Oil and Coolant Drains and Crankcase breather can be routed to the exterior

    Read More
    Spare Parts

    Spare Parts:

    Using Genuine Parts for the diesel generators reduces the risk of generating set damage that can result from the use of non-genuine parts that’s why A.T.GENERATORS supplies a complete range of high quality of spare parts for power generator engines &alternators at competitive prices. We offer genuine Perkins Engines and Leroy-Somer Alternators spare parts.

    • Engine Parts, Heads, Valves, Muffler, Crank Shaft, Pistons, Springs and more.
    • Fuel, Air and Oil Filters for the diesel engine
    • Fuel System Parts Including Pumps, Hoses, Gaskets and Fuel Injectors
    • Gaskets for generator Engine, Muffler and Fuel Systems including o-rings
    • Generator electrical components including control panel, wiring, regulators, switches, outlets and more.

    Using our Genuine Parts...The Benefits for the genset:

    • Maximise the productive life of your generating set
    • Promote longevity in the life of other component parts of the power generator
    • Promote efficiency in operation and in fuel consumption
    • Assure the highest standards of safety and functionality

    Using our Genuine Parts reduces the risk of generating set damage that can result from the use of non-genuine parts, such as...

    • Rapid wear for the generator engine parts
    • Compromised performance of the generator
    • Poor reliability
    • Higher oil and fuel consumption
    • Component damage and failure to the generator

    Read More
    Control Panel

    Control Panel:

    We have Digital & manual control panels for different types of diesel generators. The DSE701 is a Manual/Auto Start Generator Controller that offers an excellent range of engine monitoring and protection features.

    The Generator Control module has been designed to monitor

    • Low oil pressure of the genset,
    • High generator engine temperature,
    • over speed and a user defined auxiliary input.
    • It also has the capability to monitor battery charging by utilising the WL terminal on the charge alternator.

    When the Generator Control detects a fault condition it automatically shuts down the generator engine. The module also includes a remote start signal input. The input allows the module to be started from a pre-defined remote location.

    Main Features

    • Manual start
    • Engine pre-heat
    • Engine monitoring and protection features
    • Protected solid state (PSS) outputs
    • Front panel mounting
    • Remote start
    • LED indicators

    Benefits

    Multiple generator engine parameters are monitored simultaneously

    Operation

    Manual Mode:

    • The module is started using the on-board key/buttons
    • The user turns the key to the hand position
    • The generator engine pre-heat button is then pressed for the required time
    • The start button is then pressed to start the diesel engine
    • To stop the generator engine the key needs to be turned to the off position

    Automatic Mode:

    • The key needs to be permanently left in the hand position
    • The module is powered up by the remote start signal
    • The pre-heat function is automatically carried out and then the generator engine is started
    • To stop the generator engine the remote switch is turned to the ‘off’ position

    Read More
    ATS & MTS

    ATS & MTS:

    A.T.GENERATORS offers a full range of transformers used for the diesel generators. We also supply Automatic Mains Failure (AMF), load sharing and more.

    • Single Phase Automatic Transfer Switches
    • 3 Phase Automatic Transfer Switches
    • Automatic Transfer Switches are an integral part of the power generation process, allowing smooth and immediate transfer of electrical current between multiple sources and the load. When the generator is operating, the transfer switch prevents dangerous feedback of current to the utility’s system. It also ensures that different power sources are fully synchronized before their power is combined or loads are transferred, which is imperative for safe operation.
    • The transfer switches sense when utility power is interrupted, and starts up the generator if the utility power remains absent. In about five to ten seconds, when the generator is producing full power, the transfer switch disconnects the load from the utility and connects it to the generator, restoring electricity to the load. The transfer switch continues to monitor utility power, and when it is restored, switches the load from the generator back to the utility. Once the generator is disconnected, it goes through a cool-down routine and is automatically shut down the generators.
    • By combining ATS with our own diesel generators, we are able to offer a complete power generation package that we support and warrant.
    • MTS( manual transfer switch) used with the diesel generators.
    • Same as above, but manual.

    Read More
    Synchronizers

    Synchronizers

    A.T.GENERATORS Perform different types of synchronizing projects between the diesel generators.

    • Direct upgrade/replacement using custom synchronizing panels
    • Engineered upgrades of legacy synchronizing systems using automatic synchronizing relays
    • Engineered upgrades of synchronizing systems using utility-grade PLCs for multiplexing multiple generators

    Synchronizing panel will operate on an automatic mains failure system, so that when the main supply is interrupted on one or all phases (after an adjustable delay period) the generator sets will start-up together. After an initial warm-up period (adjustable) the generators will synchronize with each other by means of motorized circuit breakers or contactors onto a common buss bar. Next, the motorized change-over switch will be closed and the load connected to the main distribution box.

    The load share units continuously monitor the load and during low demand periods one or two generators will be shut down to save on fuel consumption. As demand rises again the second generator and third generator will be restarted, synchronized and reconnected to load. When the AMF control unit detects that the main supply has been restored an adjustable observation period is activated before the main supply is reconnected. A cool down period will then follow, after which the generator sets will be shut down.


    Read More